The Concrete Society’s TR34 Defined Movement (4th Edition) Classifications

The flatness classification that Face Consultants recommend is that contained within table 3.2 of the Concrete Society’s Technical Report No.34 (4th Edition), in which section 3 discusses flatness requirements for very narrow aisle (VNA) warehouse floors, how to achieve them, the allowable values of the properties of flatness and how to measure them.

Table 3.2: Permissible limits on Properties dZ, dX, d2Z and d2X in defined-movement areas.

Floor Classification Racking top beam height Property ZSLOPE Property dZ Property d2Z Property dX Property d2X
Calculation mm per m Z x ZSLOPE dZ x 0.75 Fixed values 2 x ZSLOPE x 1.1 Fixed values
DM1 Over 13m 1.3 Z x 1.3 Z x 1.0 2.9 1.5
DM2 8 – 13m 2.0 Z x 2.0 Z x 1.5 4.4 2.0
DM3 Up to 8m 2.5 Z x 2.5 Z x 1.9 5.5 2.5

Properties Measured

The following properties are defined in Figures 3.8 – 3.10 as follows:

Property Z: The transverse dimension between the centres of the truck front wheels, in m.

Property X: The longitudinal dimension between the centre of the front and rear truck axles. This is taken to be a fixed 2m.

Property ZSLOPE: The cross-aisle slope between the centres of the truck front wheels in mm/m.

Property dZ: The elevational difference in mm between the centres of the truck front wheels.

Property dX: The elevational difference in mm between the centre of the front axle and the centre of the rear axle.

Permissable Limits

Table 3.2 details the allowable values of the properties of flatness for differing categories.

N.B The values shown for dX and d²X are based on a longitudinal dimension of 2000mm (this is a fixed dimension)

It is not possible to specify and impose these limits for defined movement unless the exact design of the VNA installation is known before construction. The choice of classification to specify is dependent upon the height of the top beam of the racking.

However, the recommendations of the VNA fork lift truck manufacturer should also be sought, as each model is designed to cater for different requirements and is therefore affected differently by surface regularity.

Related Documents

Face Profileograph

Checking for compliance to Table 3.2 with the Face Profileograph

Checking for compliance to Table 3.2 with the Face Profileograph.

Different Set Ups Available

checking a range of defined movement specifications

A range of Profileograph set ups are available for us to check a range of defined movement specifications from across the world.

Measurement Standards

TR34 4th Edition

TR34 4th Ed Chapter 3

The Concrete Society’s TR34 (4th Ed) Chapter 3

(Current Version)

EN 15620

EN 15620

(2008)

Comparison table for Defined Movement Specifications

Flatness Comparisons

Comparison table for Defined Movement Specifications

TR34 3rd Edition

TR34 3rd Ed Chapter 4

The Concrete Society’s TR34 Free Movement (3rd Ed) Chapter 4

(Previous Version)*

* The Concrete Society’s TR34 3rd edition was superseded by the 4th edition in August 2013.
† Replaced 2021. New version has no flatness requirement.